1. | Disconnect the evaporative emission hoses (1) from the canister . Mark the hoses if necessary for reconnection. Do not remove the hoses from the opposite end connections. | |
2. | Use a jack to support the front of the motor. Remove the canister from the brackets. Remove the canister bracket. Save the motor mount screws. | |
3. | Install the canister to the new bracket. | |
4. | Install the canister assembly to the motor mount using the OE screws. Tighten the screws to 24.4–29.9 N·m (18–22 ft-lbs). | |
5. | Remove the jack. | |
6. | Connect the hoses to the canister. |
1 | Canister hoses (3) |
2 | Flat washer (2) |
3 | Spring washer (2) |
4 | Socket head screw (2) |
5 | Screws (2) |
6 | Canister mounting bracket |
7 | Canister |
8 | Cable Straps (3) |
Item | Description (Quantity) | Part Number |
---|---|---|
1 | Canister bracket | Not Sold Separately |
2 | Cable strap (3) | 10039 |