1. | See Figure 1 Secure air filter element (1) to air cleaner backplate using screws (A). Tighten. Torque: 5–7 N·m (44–62 in-lbs) | |
2. | Carefully remove and discard the original air cleaner cover insert from air cleaner (2). Remove any residual adhesive on the cover with mineral spirits. | |
3. | To verify surface cleanliness, clean the insert area with a mixture of 50 to 79% isopropyl alcohol and 30 to 50% distilled water. Allow to dry thoroughly. NOTE The air cleaner cover insert in this kit utilizes 3M™ Dual Lock™ Re-closable tape. The tape can be separated and pressed back together for service access to the air cleaner cover screw. | |
4. | Peel liner from adhesive backing of air cleaner cover insert (2). Position insert over air cleaner cover (B) without touching adhesive on cover surface. Line up insert with recess in air cleaner cover. | |
5. | Press air cleaner cover insert firmly against the cover all around, and hold pressure for 30 seconds. After releasing pressure, avoid direct contact with the insert for about 20 minutes. NOTE Allow at least 24 hours after applying the insert before exposing the area to vigorous washing, strong water spray or extreme weather. The adhesive bond will increase to maximum strength after 72 hours at normal room temperatures. | |
6. | Carefully pry air cleaner insert (3) off the air cleaner cover to access the air cleaner cover mounting screw hole. | |
7. | Install air cleaner cover screw (C). Tighten. Torque: 6–8 N·m (53–71 in-lbs) |
Item | Description (Quantity) | Part Number |
---|---|---|
1 | Air filter element | Not sold separately |
2 | Air cleaner insert | 61300835 |
Items mentioned in text, but not included in kit: | ||
A | Air cleaner screw (3) | |
B | Air cleaner cover | |
C | Air cleaner cover screw |