1. | Clean lower area of induction module side of backplate. Use a mixture of 50-70% isopropyl alcohol and 30-50% distilled water. Allow to dry completely. Align adhesive backed clip (8) with opening upwards, and affix in six o'clock position. Clamp wire previously removed from original equipment backplate. | |
2. | See Figure 1. Install two O-rings (1) from kit in grooves around breather screw holes on induction module side of backplate assembly (2). | |
3. | Peel the protective strip off the gasket (3) and place the adhesive side onto the backplate. Position the gasket carefully before firmly pressing the gasket into place. | |
4. | Insert breather screws (A) through the backplate. | |
5. | Apply Loctite 243 (blue) to breather screw threads and mating tapped holes in cylinder head. | |
6. | Thread screws into cylinder head but do not tighten. | |
7. | Thread air cleaner mounting studs (4) all the way through the backplate (2) and gasket (3) until the screw threads are captured in induction module. Leave fasteners loose. | |
8. | Alternately tighten two breather screws (A) to 13.6–16.3 N·m (120–144 in-lbs). | |
9. | Press breather plugs (5) into breather screw cavities and onto ends of breather screws, aligning tubes with recesses in backplate. | |
10. | Tighten three air cleaner studs (4) to 6.2–6.8 N·m (55–60 in-lbs). |
1. | See Figure 1. Secure air filter element (7) to air cleaner mounting studs (4) using screws (6). Tighten screws to 6.2–6.8 N·m (55–60 in-lbs). | |
2. | Carefully remove and discard the original air cleaner cover insert from air cleaner cover (B). Remove any residual adhesive on the cover with mineral spirits. | |
3. | To verify surface cleanliness, clean the insert area with a mixture of 50-70% isopropyl alcohol and 30-50% distilled water. Allow to dry completely. | |
4. | Peel liner from adhesive backing of air cleaner cover insert (9). Position insert over air cleaner cover (B) without touching adhesive on cover surface. Line up top of insert with top of oval air cleaner cover. | |
5. | Press air cleaner cover insert firmly against the cover all around, and hold pressure for 30 seconds. After releasing pressure, avoid direct contact with the insert for about 20 minutes. NOTE Allow at least 24 hours after applying the insert before exposing the area to vigorous washing, strong water spray, or extreme weather. The adhesive bond will increase to maximum strength after about 72 hours at normal room temperatures. | |
6. | Align air cleaner cover adapter (8) with filter element channel and mounting screws. Set adapter into place, verifying that adapter rib fits fully into element channel. | |
7. | Align air cleaner cover to cover adapter. Tighten screw securely. Tighten to 4.1–6.8 N·m (36–60 in-lbs). |
Item | Description (Quantity) | Part Number |
---|---|---|
1 | O-ring (2) | 11292 |
2 | Backplate assembly, black Backplate assembly, chrome | 29119-08 29170-08 |
3 | Gasket, backplate | 29059-88A |
4 | Stud, air cleaner (3) | 29447-99A |
5 | Plug, breather (2) | 29557-05 |
6 | Screw, air cleaner element (3) | 3938 |
7 | Filter element | 29385-08 |
8 | Adapter, air cleaner | 29392-08 |
9 | Insert, cover | 29398-08 |
10 | Clip, adhesive | 10102 |
Items mentioned in text, but not included in kit: | ||
A | Breather screw (2) | |
B | Air cleaner cover | |
C | Screw |