CONTACT | TREATMENT |
---|---|
External | Flush with water. |
Internal | Drink large quantities of
milk or water, followed by milk of magnesia,
vegetable oil or beaten eggs. Get immediate medical attention. |
Eyes | Flush with water. Get
immediate medical attention. |
1 | Contents are corrosive |
2 | Wear safety glasses |
3 | Contents are explosive |
4 | Keep flames away |
5 | Read instructions |
6 | Keep away from children |
READING IN VOLTS | PERCENT OF CHARGE |
---|---|
12.7 | 100 |
12.6 | 75 |
12.3 | 50 |
12.0 | 25 |
11.8 | 0 |
1. | Perform a voltmeter test to determine the state of charge. If battery needs to be charged, proceed to the next step. | |
2. | Place the battery on a level surface. NOTE
| |
WARNING Unplug or turn OFF battery charger before connecting charger cables to battery. Connecting cables with charger ON can cause a spark and battery explosion, which could result in death or serious injury. (00066a) WARNING Connect positive (+) battery cable first. If positive (+) cable should contact ground with negative (-) cable connected, the resulting sparks can cause a battery explosion, which could result in death or serious injury. (00068a) WARNING Disconnect negative (-) battery cable first. If positive (+) cable should contact ground with negative (-) cable connected, the resulting sparks can cause a battery explosion, which could result in death or serious injury. (00049a) NOTICE Do not reverse the charger connections described in the following steps or the charging system of the motorcycle could be damaged. (00214a) | ||
3. | Connect the red battery charger lead to positive (+) terminal of the battery. | |
4. | Connect the black battery charger lead to negative (-) terminal of the battery. NOTE If the battery is still in the vehicle, connect the negative lead to the chassis ground. Make sure that the ignition and all electrical accessories are turned off. | |
5. | Step away from the battery and turn on the charger. | |
WARNING Unplug or turn OFF battery charger before disconnecting charger cables from battery. Disconnecting clamps with charger ON can cause a spark and battery explosion, which could result in death or serious injury. (00067a) | ||
6. | After the battery is fully charged, turn OFF the charger and disconnect the black battery charger lead to the negative (-) terminal of the battery. | |
7. | Disconnect the red battery charger lead to the positive (+) terminal of the battery. | |
8. | Mark the charging date on the battery. |
READING (VOLTS) | PERCENT OF CHARGE | 5 AMP CHARGER | 2 AMP CHARGER | 1.5 AMP CHARGER | 0.75 AMP CHARGER |
---|---|---|---|---|---|
12.7 | 100 | - | - | - | - |
12.6 | 75 | 2 hours | 3 hours 24 minutes | 4 hours 12 minutes | 7 hours 18 minutes |
12.3 | 50 | 2 hours 54 minutes | 5 hours 48 minutes | 7 hours 18 minutes | 13 hours 42 minutes |
12.0 | 25 | 3 hours 54 minutes | 8 hours 6 minutes | 10 hours 30 minutes | 20 hours |
11.8 | 0 | 4 hours 48 minutes | 10 hours 30 minutes | 13 hours 42 minutes | 26 hours 18 minutes |
1 | Capacity |
2 | Months of non-use |
3 | Measured at 105 °F (40 °C) |
4 | Measured at 77 °F (25 °C) |