NOTE
Follow this procedure to safely deactivate electrical system.
Deactivate the electrical system whenever you perform maintenance on your motorcycle or need to disconnect/replace the battery.
NOTE
To remove/replace the main fuse, see your authorized LiveWire dealer.
To disconnect the battery, follow this procedure.
Deactivate Electrical System
1. | Ensure the FOB is present. | |
2. | Remove top cover. See Service Procedures → Top Cover. | |
3. | Place OFF/RUN switch in RUN position. | |
4. | See Figure 1. Disconnect TCU connector (5-wire), if equipped | |
5. | Disconnect siren from inside of battery cover, if equipped. | |
6. | Place OFF/RUN switch in OFF position. | |
7. | See Figure 2. Remove rear cover. NOTE vehicle OFF/RUN switch should be in OFF position for at least five minutes before Onboard Charger (OBC) connector is disconnected. | |
8. | See Figure 3. Disconnect OBC power connector. | |
Perform maintenance as needed.
Reactivate Electrical System
NOTE
Ensure the OFF/RUN switch is set back to the OFF position and FOB is present.
1. | Connect TCU connector. | |
2. | Connect siren (if equipped). | |
3. | Connect OBC connector. | |
4. | Install the rear cover. | |
5. | Install top cover. | |
Figure 1. TCU connector
Figure 2. Rear Cover (typical)
Figure 3. OBC connector