1 | Purge solenoid |
2 | Purge solenoid connector |
3 | Solenoid-to-induction module line |
4 | Canister-to-solenoid line |
5 | Tab |
1 | Vapor valve |
2 | Clip |
1 | Front belt guard |
2 | Screw and washer (4) |
1. | See Figure 4. Remove electrical panel. a. Remove screws (3). b. Carefully pull electrical panel (1) away from battery. | |
![]() Disconnect negative (-) battery cable first. If positive (+) cable should contact ground with negative (-) cable connected, the resulting sparks can cause a battery explosion, which could result in death or serious injury. (00049a) | ||
2. | See Figure 5. Disconnect negative battery cable (1) from ground stud (2). | |
3. | See Figure 4. Disconnect positive battery cable (5) from battery. | |
4. | Remove battery. | |
5. | Disconnect negative battery cable. |
1 | Electrical panel |
2 | Tab (2) |
3 | Screw and washer (2) |
4 | Battery |
5 | Positive battery cable |
6 | Positive battery terminal |
1 | Negative battery cable |
2 | Ground stud |
1. | Install negative battery cable to negative battery terminal. Torque: 6.8–7.9 N·m (60–70 in-lbs) Negative battery terminal | |
2. | Route negative cable through battery box. | |
3. | See Figure 4. Install battery (4) in battery box. | |
4. | Connect the positive battery cable (5) to the positive battery terminal (6). Torque: 6.8–7.9 N·m (60–70 in-lbs) Positive battery terminal | |
5. | See Figure 5. Connect negative battery cable (1) to ground stud (2). Torque: 6–7.5 N·m (54–66 in-lbs) Ground stud | |
6. | See Figure 4. Install electrical panel. | |
7. | Verify electrical panel tabs (2) are inserted into slots. | |
8. | Install screws (3). Torque: 5.3–6.5 N·m (47–57 in-lbs) Electrical panel screws | |
9. | See Figure 3. Position front belt guard (1). Install screws and washers (2). . Torque: 6–8 N·m (54–70 in-lbs) Belt guard screws | |
![]() Excessive pressure can build in the fuel tank if vapor valve is not mounted vertically with long fitting to top. Leaks due to excessive pressure can cause a fire or explosion, which could result in death or serious injury. (00265a) | ||
10. | See Figure 2. Press vapor valve (1) into clip (2). | |
11. | For California, Asia-Pacific, England, HDI and India Models Only: See Figure 1. Install purge solenoid. a. Install purge solenoid (1). b. Install solenoid-to-induction module and canister-to-solenoid lines (3 and 4). c. Connect purge solenoid connector (2). | |
12. | Install main fuse. See Service Procedures → Fuses. | |
13. | Install seat. See Service Procedures → Seat. | |
14. | Install side covers. See Service Procedures → Side Covers. |