1. See Figure 2. Connect the IM connector (2).
2. See Figure 1. Install IM (1) into clamp (2).
3. Install screws (3). Tighten.
Torque: 1.4–1.9 N·m (12–17 in-lbs) IM screws
1Instrument Module (IM)
2Clamp
3Screws (2)
Figure 1. Instrument Module (IM)
1IM
2IM connector
Figure 2. IM Connector