| 1. | See Electrical → LEFT HAND CONTROL MODULE (LHCM) → Install → Hand Control Module (Typical). Remove LHCM housing (2). NOTE The LHCM housing screws (1) are captive. a. Loosen screws (1). b. Remove front housing (2). | |
| 2. | Remove connectors (3). NOTE The latches on connectors are fragile. Use care when disconnecting. a. See Electrical → LEFT HAND CONTROL MODULE (LHCM) → Install → LHCM Connector (Typical). Using a pick, carefully press connector latch (1) down. b. Use a prying motion on latch while pulling on connector to remove. | |
| 3. | See Electrical → LEFT HAND CONTROL MODULE (LHCM) → Install → Hand Control Module (Typical). Release connector latch (2) and rotate switch down. | |
| 4. | See Electrical → LEFT HAND CONTROL MODULE (LHCM) → Install → LHCM Connector (Typical). Remove left hand control module. NOTE The latches on connectors are fragile. Use care when disconnecting. a. Using a pick, carefully press connector latch (1) down. b. Use a prying motion on latch while pulling on connector to remove. c. Loosen screw (5). d. Release locator (4). e. Remove hand control module (3). |